Abstract:  
Accurate localization of neural activity from electroencephalography (EEG) remains challenging due to the ill‑posed inverse problem and spatial leakage between cortical regions. Although several linear inverse methods have been proposed, their practical performance under realistic experimental conditions is not fully understood. This study compares four widely used distributed inverse solutions, minimum norm estimation (MNE), dynamic statistical parametric mapping (dSPM), standardized low‑resolution electromagnetic tomography (sLORETA), and exact LORETA (eLORETA), focusing on spatial resolution and leakage characteristics.
EEG data were collected from nineteen right‑handed participants (mean age 23 ± 3.5 years) performing two visual tasks: face detection and motion discrimination. Recordings were obtained using a 128‑channel EEG system at 2048 Hz. Spatial resolution was assessed using peak localization error (PLE) and spatial dispersion (SD) derived from point spread functions (PSF) and cross‑talk functions (CTF). Spatial leakage patterns were also examined across functionally relevant cortical networks.
Statistical comparisons revealed significant differences between inverse methods for PSF based localization accuracy, with sLORETA and eLORETA achieving near zero localization error, whereas MNE and dSPM showed larger deviations. However, under CTF analyses reflecting more realistic multi‑source activity, all methods exhibited increased localization errors and similar spatial spread. Network analyses further indicated that anatomical organization influences leakage patterns, with compact regions such as V1 demonstrating higher localization specificity than distributed visual networks.
Overall, the results indicate that no single inverse method optimizes all aspects of spatial resolution. Instead, each method reflects a trade‑off between focality, smoothness, and robustness, highlighting the importance of selecting inverse models according to the goals of EEG source analysis.
Type of Study: Original | Subject: Cognitive Neuroscience
Received: 2026/04/9 | Accepted: 2026/07/28

Add your comments about this article : Your username or Email:
CAPTCHA

Send email to the article author


Rights and permissions
Creative Commons License This work is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License.

© 2026 CC BY-NC 4.0 | Basic and Clinical Neuroscience

Designed & Developed by : Yektaweb